Technical Staff Blog

Last update on .

Tstaff will decommission the CCV Backup Service of the GPFS filesystem on the end of business day, Friday, April, 28, 2017.  We will no longer have access to the CCV tape library after that date.  The result is we will not be able to fulfill data restore requests for data older than 6 months.  Please ...

Last update on .

The certificate for the filemaker server, filemakera.ad.brown.edu, is about to expire.  In order to perform maintenance on the server, all databases on the filemakera.ad.brown.edu have been migrated to filemakerh.ad.brown.edu. The syschange is scheduled for the morning of Thursday, March 9th.  After Thursday, March 9th, the CS ...

Last update on .

There was a broken water pipe on the 3rd floor near the network closet.  One of the network switch, cit-cs-as.net.brown, was affected and is offlined.  The following CIT rooms are affected this switch outage: 115, 121, 132, and 134.

We are investigating further and will update this post as we learn more.

Update ...

Last update on .

There was a short network outage at 5pm today, affecting some of our user managed machines in Room 310 and the department's Print Host.  While disabling a set of ports on the switch a port we were not suppose to have access to was also disabled, which severed that switch's communications with the ...

Last update on .

https://bugs.debian.org/cgi-bin/bugreport.cgi?bug=855434

The version of Chromium currently installed on our managed machines is affected by the bug described at the link above.  This bug prevents the browser from completing the necessary steps for a secure connection, which results in a generic error message.

For those using Chromium, until ...

Last update on .

CIS Networking Group Scheduled Network Maintenance:

We are providing this notification that maintenance will be performed to the BC POD between the hours of 6:00 am and 8:00 am on 2/14, 2/15 and 2/16.

During this time, wired, wireless network and IPTV may experience a brief outage lasting less than ...

Last update on .

At around 11:30am today, our local DNS database became corrupted, causing domain name resolution to fail for local hosts.  This caused a series of cascading failures which rendered most local services unusable.  We restored the database and restarted our name service shortly after noon and all services should be back to normal.  We are ...

Last update on .

The CS Department mailing list server was down for much of today after an update caused a local misconfiguration.  An update to our Sympa software which was automatically installed overnight broke a local configuration script and caused the service to be unresponsive from around 12:30am this morning until about 7pm this evening.  No messages ...